StatLock® IV Select Stabilization Device

StatLock® IV Select Stabilization Device

StatLock® IV Select Stabilization Device image
  • The StatLock® IV Select Stabilization Device is the ultimate, state-of-the-art stabilization device.
  • Universally compatible with all peripheral IV catheters – available in adult and pediatric sizes.
  • Quickest and easiest of all StatLock® IV Stabilization Devices.
  • Unique entry angle of retainer is designed to prevent catheter kinking which could lead to occlusion.
  • Includes patented luer-lock extension set – just snap the retainer over the custom-crafted luer, peel and place.
  • Breathable anchor pad made from nonabsorbent tricot polyester.
  • Sterile, DEHP-free and latex-free.
  • The StatLock® IV Select Stabilization Device is now available for low-pressure power injection for patients needing a contrast study.

Features


StatLock® Stabilization Devices are a more effective alternative to tape in helping improve clinical outcomes, quality of care and economic efficiencies.   The StatLock® IV Select Stabilization Device snap fits onto the proprietary extension set behind the luer.  Available along with an array of valve systems. Available in adult and pediatric sizes.

Please consult product labels, IFU and package inserts for any indications, contraindications, hazards, warnings, cautions and instructions for use.

Specifications

No Valve

Stand Alone/Kit Configuration Size Description Item Number Pkg Natural Latex?
Stand Alone No Valve Pediatric IV SELECT Pediatric Micro 4" IV0502 25/case No
Stand Alone No Valve Pediatric IV SELECT Pediatric Macro 6" IV0503 25/case No
Stand Alone No Valve Adult IV SELECT Micro 6" IV0521 25/case No
Stand Alone No Valve Adult IV SELECT Macro 6" IV0525 25/case No
Stand Alone No Valve Adult IV SELECT Macro 6" Power INJ 325 psi; 10 mL/sec IV0525P 25/case No
Stand Alone No Valve Adult IV SELECT Micro 12" IV0527 25/case No
Stand Alone No Valve Adult IV SELECT No Ext Set IV0528 25/case No
Stand Alone No Valve Adult IV SELECT Micro 9" Bifurcated IV0529 25/case No
Stand Alone No Valve Adult IV SELECT Macro 7" Bifurcated IV0531 25/case No
Stand Alone No Valve Pediatric IV SELECT Pediatric Micro 6" IV0597 25/case No
Start Kits No Valve Adult IV SELECT KIT Macro SEPP IVK0117 50/case No
Start Kits No Valve Adult IV SELECT KIT Micro SEPP IVK0121 50/case No
Start Kits No Valve Adult IV SELECT KIT Macro FREPP IVK0177 50/case No

SmartSite

Stand Alone/Kit Configuration Size Description Item Number Pkg Natural Latex?
Stand Alone SmartSite Pediatric IV SELECT Pediatric Micro 4" Smartsite IV0506 25/case No
Stand Alone SmartSite Adult IV SELECT Macro 6" Power INJ 325 psi; 10 mL/sec IVO563P 25/case No
Stand Alone SmartSite Adult IV SELECT Macro 7" Bifurcated 2 Smartsite IV0532 25/case No
Stand Alone SmartSite Adult IV SELECT Macro 6" Smartsite IV0563 25/case No
Stand Alone SmartSite Adult IV SELECT Macro 6" Smartsite Y-St IV0564 25/case No
Stand Alone SmartSite Adult IV SELECT Micro 6" Smartsite IV0565 25/case No
Stand Alone SmartSite Adult IV SELECT Micro 9" Bifurcated 2 Smartsite IV0566 25/case No
Start Kits SmartSite Adult IV SELECT KIT Micro 6" Smartsite SEPP IVK0122 50/case No
Start Kits SmartSite Adult IV SELECT KIT Macro 6" Smartsite SEPP IVK0124 50/case No
Start Kits SmartSite Adult IV SELECT KIT Pediatric Macro 6" Smartsite SEPP IVK0126 50/case No
Start Kits SmartSite Adult IV SELECT KIT Macro Smartsite FREPP w/gloves IVK0133 50/case No
Start Kits SmartSite Adult IV SELECT KIT Micro 6" Smartsite FREPP IVK0135 50/case No
Start Kits SmartSite Adult IV SELECT KIT Macro 6" Smartsite FREPP IVK0136 50/case No
Start Kits SmartSite Adult IV SEL KIT Macro 6" Bonded Smartsite FREPP/border TEG IVK0140 50/case No
Start Kits SmartSite Adult IV SELECT KIT Macro Smartsite -Y-set with gloves IVK0145 50/case No
Start Kits SmartSite Adult IV SELECT KIT Micro Smartsite FREPP with gloves IVK0146 50/case No
Start Kits SmartSite Adult IV SELECT KIT PEDS Micro 6" Smartsite FREPP IVK0153 50/case No

SmartSite Plus

Stand Alone/Kit Configuration Size Description Item Number Pkg Natural Latex?
Stand Alone SmartSite Plus Adult IV SELECT Macro 7" Bifurcated 2 Smartsite Plus IV0533 25/case No
Stand Alone SmartSite Plus Pediatric IV SELECT Pediatric Micro Smartsite Plus IV0535 25/case No
Stand Alone SmartSite Plus Adult IV SELECT Micro 6", Smartsite Plus IV0562 25/case No
Stand Alone SmartSite Plus Adult IV SELECT Macro 6" Smartsite Plus IV0574 25/case No
Stand Alone SmartSite Plus Adult IV SELECT Micro 9" Bifurcated 2 Smartsite Plus IV0585 25/case No
Start Kits SmartSite Plus Adult IV SELECT KIT Macro 6" Smartsite Plus FREPP IVK0161 50/case No
Start Kits SmartSite Plus Adult IV SELECT KIT Micro 6" Smartsite Plus FREPP IVK0162 50/case No

Clave

Stand Alone/Kit Configuration Size Description Item Number Pkg Natural Latex?
Stand Alone Clave Adult IV SELECT Micro Clave IV0540 25/case No
Stand Alone Clave Adult IV SELECT Macro Clave IV0541 25/case No
Stand Alone Clave Adult IV SELECT Micro Bifurcated 2 Clave IV0543 25/case No
Stand Alone Clave Adult IV SELECT Macro Bifurcated 2 Clave IV0545 25/case No
Stand Alone Clave Pediatric IV SELECT PEDS Micro Clave IV0548 25/case No
Start Kits Clave Adult IV SELECT KIT Macro 6" Clave FREPP IVK0163 50/case No
Start Kits Clave Adult IV SELECT Micro 6" Clave FREPP IVK0164 50/case No

MicroClave

Stand Alone/Kit Configuration Size Description Item Number Pkg Natural Latex?
Stand Alone MicroClave Adult IV SELECT Micro 6" Micro Clave IV0550 25/case No
Stand Alone MicroClave Adult IV SELECT Macro 6" Micro Clave IV0551 25/case No
Stand Alone MicroClave Adult IV SELECT Micro Bifurcated 2 Micro Clave IV0553 25/case No
Stand Alone MicroClave Adult IV SELECT Macro Bifurcated 6" 2 Micro Clave IV0555 25/case No
Stand Alone MicroClave Pediatric IV SELECT PEDS Micro Clave IV0558 25/case No
Start Kits MicroClave Adult IV SELECT Macro 6" Micro Clave FREPP IVK0165 50/case No
Start Kits MicroClave Adult IV SELECT Micro 6" Micro Clave FREPP IVK0166 50/case No

Ultrasite

Stand Alone/Kit Configuration Size Description Item Number Pkg Natural Latex?
Stand Alone Ultrasite Adult IV SELECT Micro 6" Ultrasite IV0571 25/case No
Stand Alone Ultrasite Adult IV SELECT Macro 6" Ultrasite IV0572 25/case No
Stand Alone Ultrasite Adult IV SELECT Macro 6" Ultrasite Power INJ 300 psi; 4 mL/sec IV0572P 25/case No
Stand Alone Ultrasite Adult IV SELECT Macro Bifurcated 9" 1 Ultrasite IV0584 25/case No
Stand Alone Ultrasite Adult IV SELECT Macro Bifurcated 7" 2 Ultrasite IV0591 25/case No
Start Kits Ultrasite Adult IV SELECT KIT Micro 6" Ultrasite FREPP IVK0118 50/case No
Start Kits Ultrasite Adult IV SELECT KIT Macro 6" Ultrasite FREPP IVK0119 50/case No
Start Kits Ultrasite Adult IV SELECT KIT Micro 8" Ultrasite FREPP IVK0125 50/case No
Start Kits Ultrasite Adult SL IV SELECT Macro 7" Bifurcated, Ultrasite FREPP IVK0154 50/case No
Specifications subject to change without notice.

Resources

Please refer to the below-listed Instructions for Use (IFUs) for any indications, contraindications, hazards, warnings and cautions.

Video

  • StatLock® IV Select Stabilization Device Application Procedure Video03:57
  • StatLock® IV Select Stabilization Device Removal Procedure Video01:38
  • StatLock® IV Select Stabilization Device In-Service Video05:35

Prescriptive Information

INDICATIONS FOR USE: The StatLock® stabilization device is compatible for medical tubes and catheters.

CONTRAINDICATIONS: Known tape or adhesive allergies. Known sensitivity to benzoin. (Zinc Oxide PICC Neonatal Universal)

WARNINGS AND PRECAUTIONS

  • Do not use the StatLock® stabilization device where loss of adherence could occur, such as with a confused patient, unattended access device, diaphoretic or non-adherent skin, or when the access device is not monitored daily.
  • Observe universal blood and body fluid precautions and infection control procedures, during the StatLock® stabilization device application and removal.
  • Suture the StatLock® stabilization device pad to skin if necessary or deemed necessary.
  • Avoid the StatLock® stabilization device contact with alcohol or acetone, both can weaken bonding of components and the StatLock® stabilization device pad adherence.
  • Minimize catheter manipulation during StatLock® stabilization device application and removal.
  • Remove oil and moisturizer from targeted skin area.
  • The StatLock® stabilization device pad adherence and catheter/tube position should be routinely inspected.
  • Orient the StatLock® stabilization device so arrows point toward the catheter tip.
  • The StatLock® stabilization device should be replaced every 7 days.
  • A StatLock® stabilization device luer-lock connector must be used to secure venous and arterial catheters.
  • Always apply the adhesive strip to central venous and arterial catheters at or near the insertion site when using a StatLock® stabilization device.
  • This is a single use device. Reuse/and or repackaging may create a risk of patient or user infection, compromise the structural integrity and/or essential material and design characteristics of the device, which may lead to device failure, and/or lead to injury, illness or death of the patent.
  • Do not re-sterilize. The sterility of the single use device is not guaranteed following re-sterilization because of an indeterminable degree of potential pyrogenic or microbial contamination which may lead to infection complications. Re-sterilization may compromise the structural integrity, essential material and/or design characteristics and may lead to an unpredictable loss of functionality and/or device failure.
  • Special Patient Population
    • Do not use alcohol or acetone containing products on pre-term infants

Clinical Outcomes

The Unrivaled Evidence You Need To Proceed

Clinical studies comparing the stabilization of catheter IVs using tape versus StatLock® stabilization devices demonstrate
that StatLock® stabilization devices are unrivaled in helping to improve patient outcomes, quality of care and economic efficiencies. 5,2,11

The results demonstrate that the innovative designs of StatLock® stabilization devices provide superlative results in promoting healthcare worker safety and patient satisfaction. The comparative data makes a persuasive case as to why StatLock® stabilization devices are more effective than traditional forms of tape and suture stabilization to achieve the positive outcomes
you seek.

Proven to Reduce Complications

StatLock® stabilization device for Peripheral IV Catheter:

  • Lowers the rate of total IV complications by approximately 67% 5
  • Decreases IV total complication rate from 48% to 16% 5
  • Decreases phlebitis rate by approximately 80% 5
  • Decreases rate of tape-related skin damage which has been documented to be as high as 54% 2,11

StatLock® stabilization device for PICC and Central Line Catheter:

  • When a sterile securement device (StatLock® stabilization device) has been used routinely, total PICC complications and restarts in a hospital have decreased by 45% 2
  • When compared to suture stabilization, StatLock® Stabilization Devices eliminate sharps injuries to health care workers when they are securing central catheter lines 29,30,15 2,11

StatLock® stabilization device for Arterial Catheter:

  • Reduces unscheduled arterial catheter restarts by 49% 12

StatLock® Neonatal stabilization device:

  • Tape doesn't adhere well to the plastic cannula; in 74% of tape specimens tested in one hospital, pathenogenic bacteria contaminated the tape 13

StatLock® Epidural stabilization device:

  • Designed to prevent epidural catheter migration, disconnection and/or dislodgement which could interrupt anesthesia

For references, click here

Quality of Care

The Unrivaled Evidence You Need To Proceed

Clinical studies comparing the stabilization of catheter using tape versus StatLock® stabilization devices demonstrate that
the StatLock® stabilization devices are unrivaled in helping to improve patient outcomes, quality of care and economic
efficiencies. 5,2,11

The results demonstrate that the innovative designs of StatLock® stabilization devices provide superlative results in promoting healthcare worker safety and patient satisfaction. The comparative data makes a persuasive case as to why StatLock® stabilization devices are more effective than traditional forms of tape and suture stabilization to achieve the positive outcomes
you seek.

Enhances Patient Care

StatLock® stabilization device for Peripheral IV Catheter:

  • Meets the 2006 INS Standards that state "whenever feasible, using a manufactured catheter stabilization device
    is preferred."31
  • Increases IV catheter dwell times from 44 hours to 98 hours 4,27
  • Decreases unscheduled IV catheter restarts from approximately 71% to 17% 5
  • Eliminates the use of non-sterile tape which has a 74% contamination rate StatLock® stabilization device for
    PICC Catheter 13

StatLock® stabilization device for PICC Catheter:

  • Meets the 2006 INS Standards that state "Whenever feasible, using a manufactured catheter stabilization device
    is preferred." 31
  • Eliminates suture related needlesticks 18,29,30

StatLock® stabilization device for Arterial Catheter:

  • Meets the 2006 INS Standards that state "Whenever feasible, using a manufactured catheter stabilization device
    is preferred." (31)

For references, click here

Economic Efficiencies

The Unrivaled Evidence You Need To Proceed

Clinical studies comparing the stabilization of catheter IVs using tape versus StatLock® stabilization devices demonstrate
that the StatLock® stabilization devices are unrivaled in helping to improve patient outcomes, quality of care and economic efficiencies. 5,2,11

The results demonstrate that the innovative designs of StatLock® stabilization devices provide superlative results in promoting healthcare worker safety and patient satisfaction. The comparative data makes a persuasive case as to why StatLock® stabilization devices are more effective than traditional forms of tape and suture stabilization to achieve the positive outcomes
you seek.

Saves Time and Money

StatLock® stabilization device for Peripheral IV Catheter:

  • Decreases material costs - 55 fewer IVs per 100 catheter starts5
  • Saves an average of 29 minutes per IV treatment compared to tape11
  • May provide hospitals an estimated overall cost savings in the range of $277,000 per year5

StatLock® stabilization device for PICC and Central Line Catheter:

  • Eliminates the associated costs of needlestick injuries - nearly $3,000 per incident, even when it doesn't result in
    an infection29
  • Significantly reduces the cost of maintaining a PICC line and the complication costs associated with the catheter10

StatLock® stabilization device for Arterial Catheter:

  • StatLock® stabilization device usage is essentially cost neutral12

For references, click here