Power-Trialysis® Short-Term Dialysis Catheter

  • Power injectable third lumen
  • Double barrel lumen design
  • Kink Resistant Catheter Design
  • Symmetrical Tip
  • Catheter Length Options
  • Maximal Barrier Trays
  • Straight or curved extension legs
  • Alphacurve® catheter options

Available sizes:13 Fr.

Power Trialysis® Short-Term Dialysis Catheter

Features

Enhanced Acute Dialysis Care

The Power-Trialysis® Short-Term Triple Lumen Dialysis Catheter is the first power injectable dialysis catheter in the world and provides flow rates of up to 400 mL/min on average with straight configurations, and 350 mL/min with Alphacurve® configurations when tested in vitro as well as the benefits of a third lumen for power injection of contrast media, central venous pressure monitoring, intravenous therapy, and blood draws. The symmetrical tip design allows for 2% recirculation on average when lines run in forward and in reverse.1

The 17 gauge third lumen exits distal to the dialysis lumens and is easily identified by its purple extension leg, marked “POWER INJECTABLE.” Contrast media may be injected at rates up to 5 mL/sec or the maximum pressure of power injectors of 300 psi. The Power-Trialysis® Short-Term Triple Lumen Dialysis Catheter allows patients to receive therapies and Contrast-Enhanced Computed Tomography (CECT) scans without the need for additional access. Power-injected CECT scans produce excellent images to help better manage patient care.

"First power injectable dialysis catheter in the world"

Power Trialysis® Short-Term Dialysis Catheter Tip

Optimal PERFORMANCE Features1

  • Double barrel lumen design
    allows for flows of up to 400 mL/min in dialysis lumens
  • Kink Resistant Catheter Design
    resists kinking while providing stiffness for insertion
  • Symmetrical Tip
    allows for 2% recirculation on average in both forward and reverse directions
  • Tip is softer than shaft

Unique Benefits of the Power-Trialysis® Short-Term Triple Lumen Dialysis Catheters

13 French Power-Trialysis® Short-Term Triple Lumen Catheters are available in a variety of lengths including a long 30 cm length for femoral placements excluding Alphacurve® configurations. Catheters are available in three configurations – with straight and curved extension legs, and Alphacurve® configuration– and in standard kits and full maximal barrier precautions trays. Full maximal barrier precautions trays help clinicians comply with IHI, CDC, and OSHA guidelines and feature a full body drape (70” x 110”), a surgical gown, and safety components.

FLEXIBILITY & UTILITY for you and your patient

  • Dialysis (12 Ga) Lumens indicated for hemodialysis,
    hemoperfusion, and apheresis
  • Third (17 Ga) Lumen exits distal to the dialysis lumens and is indicated for intravenous therapy including infusion of medication and blood draws, power injection of contrast media, and central venous pressure monitoring
  • Catheter Length Options catheters are available in 12.5 cm, 15 cm, 24 cm, and 30 cm (lengths vary by catheter configuration)
Power Trialysis Three
Power Trialysis® Short-Term Dialysis Catheter

DESIGN

Flow Rate of up to 400 ml/min with straight configurations
and up to 350 ml/min with Alphacurve® configurations with pressures of less than 250 mmHg in dialysis lumens

Double Barrell Lumen Design
permits higher flows than competitive design1

Alphacurve® catheter options are available
in 12.5 cm, 15 cm, and 24 cm. The Alphacurve® catheter allows for extension legs to be directed away from patient's hair, ear and mouth area.

KINK CHARACTRISTICS


  • 13 Fr. Oval Catheter Shaft designed for excellent kink resistance
  • More Kink Resistant than competitive 12 Fr. triple lumen dialysis catheter1
PowerTrialysis® No Kink

Maximal Barrier Trays

Feature a full body drape (70" x 110"), surgical gown, and safety components.

Max Barrier Precaution

Maximal barrier precautions help you comply with the latest guidelines from:

CDC Logo, Center For Disease ControlCenters for Disease Control (CDC) Guidelines
IHI, Institute for Healthcare ImprovementLogo Institute for Healthcare Improvement's (IHI) 5 Million Lives Campaign
OSHA, Occupational Safety & Health Administration logo Occupational Safety & Health Administration (OSHA) Guidelines

1 Bench test data on file.

Please consult product labels, IFU, and package inserts for any indications, contraindications, hazards, warnings, cautions, and instructions for use.

Kit Components

Description Tray Kit
Catheter 1 1
Adhesive Dressing 1 1
Aspiration Device 2 0
Attachable Suture Wing 1 1
Bouffant Cap 1 0
ChloraPrep™ Solution One-Step Applicator 2 0
End Cap 3 3
Drape, Body, Fenestrated 70 in. x 110 in. 1 0
Dual Ended, Marked Guidewire 70 cm x 0.89 mm (0.035 in.) 1 1
Dualator® Vessel Dilator 11-13 Fr. 1 1
Dualator® Vessel Dilator 12-14 Fr. 1 1
Gloves 1 0
Gown 1 0
Introducer Needle, 18 Ga. x 7 cm (2.75 in.) 0 1
Lidocaine HCI 1%, 5 ml Ampule 1 0
Mask 2 0
Needle Holder 1 0
Safety Introducer Needle, 18 Ga. x 7 cm (2.75 in.) 1 0
Safety Needle, 22 Ga. x 4 cm (1.5 in.) 1 0
Safety Needle, 25 Ga. x 1.6 cm (0.625 in.) 1 0
Safety Scalpel 1 0
Sodium Chloride (Saline) 0.9% 10 ml Ampule 3 0
Sponges, Gauze 10 cm x 10 cm (4 in. x 4 in.) 6 0
Suture with Curved Needle 1 0
Syringe, Luer Lock, 12 ml 3 0
Syringe, Luer Slip, 6 ml 2 0
Syringe, Luer Lock, 6 ml 1 0

Frequently Asked Questions


CATHETER INDICATIONS AND MATERIALS

When is a Triple Lumen dialysis catheter indicated rather than a Dual Lumen dialysis catheter?

The physician will determine this based on the patient needs. The Power-Trialysis® Short-Term Triple Lumen Dialysis Catheter is suitable for patients requiring other therapies concurrent with dialysis. The third lumen is completely independent from the two dialysis lumens and is indicated for power injection of contrast media, central venous pressure monitoring and can be used for blood draws and fluid or medication delivery without the need for a separate access.

What are indications for use of the Power-Trialysis® Catheter dialysis lumens?

The Power-Trialysis® Catheter dialysis lumens are indicated for use in attaining short-term (less than 30 days) vascular access for hemodialysis, hemoperfusion, and apheresis treatments.

What are the indications for use of the Power-Trialysis® Catheter third lumen?

The Power-Trialysis® Catheter third lumen is indicated for intravenous therapy, power injection of contrast media, and central venous pressure monitoring. The distal lumen can also be accessed for blood draws and infusion of medications. The maximum recommended infusion rate is 5 mL/sec for power injection of contrast media.

Please note that catheter indication for power injection of contrast media implies the catheter’s ability to withstand the procedure, but it does not imply appropriateness of the procedure for a particular patient. A suitably trained clinician is responsible for evaluating the health status of a patient as it pertains to a power injection procedure.

What are the contraindications?

Exceeding the maximum flow rate of 5 mL/sec or the maximum pressure of power injectors of 300 psi may result in catheter failure and/or catheter tip displacement.

What materials comprise the Power-Trialysis® Catheter?

The Power-Trialysis® Catheter connectors for the dialysis lumens (blue and red) are made from Delrin™ polyacetal, the power injection lumen connector (purple) is made from Isoplast™ polyurethane, the extension legs from Tecothane™ polyurethane, and the catheter shaft is made from thermosensitive Bodysoft® polyurethane which softens at body temperature.

The product and packaging do not contain natural rubber latex.

CATHETER PERFORMANCE

What flow rate does Power-Trialysis® Catheter achieve?

The straight and curved extension leg Power-Trialysis® Catheter configurations flows at 400 mL/min with low arterial/venous pressures (less than 250 mmHg). The Alphacurve® Power-Trialysis® configuration flows at 350 mL/min for all lengths with low arterial venous pressure (less than 250 mmHg).

What is the recirculation rate of the Power-Trialysis® Catheter?

The rate of recirculation of the dialysis lumens is 2% on average in both the forward and reverse directions when tested in vitro.

What are the gravity flow rates for the Power-Trialysis® Catheter third lumen?

The gravity flow rates for the Power-Trialysis® Catheter third lumen with 1 meter of water infusion pressure vary by catheter length and are listed in the Instructions for Use.

POWER INJECTION

For how many cycles of power injection was the Power-Trialysis® Catheter third lumen tested?

Power-Trialysis® Catheter testing included 10 power injection cycles on the third lumen.

What is the maximum contrast injection rate for power injection using the Power-Trialysis® Catheter?

The maximum contrast injection rate is 5 mL/sec or the maximum pressure of power injectors of 300 psi. Only the lumen marked “POWER INJECTABLE” should be used for power injection of contrast media.

CATHETER AND KIT OPTIONS

What is the French size of the Power-Trialysis® Catheter?

The Power-Trialysis® Catheter outer diameter is 13 French and offers dialysis lumens with high flows and a third lumen for intravenous therapies, power injection of contrast media, and central venous pressure monitoring. The third lumen is 17 gauge and is completely independent and exits distal to the dialysis lumens. The dialysis lumens are large 12 gauge lumens that allow for flows of up to400 mL/min.

Why is the Power-Trialysis® Catheter oval?

The oval shape provides superior kink resistance compared to a round shaft catheter.

In what configurations does the Power-Trialysis® Catheter come?

The Power-Trialysis® Catheter is available in both straight and curved extension leg configurations, and Alphacurve® (curved catheter body) configurations.

In what insertion lengths does the Power-Trialysis® Catheter come?

The Power-Trialysis® Catheter is available in 12.5 cm (curved extension leg and Alphacurve® configurations only), 15 cm, 20 cm, and 24 cm (straight extension leg and Alphacurve® configurations only), and 30 cm (straight extension leg configuration only).

In what kit configurations is the Power-Trialysis® Catheter available?

The Power-Trialysis® Catheter is available in both standard kit and full trays. Full maximal barrier precautions trays are compliant with CDC, IHI, and OSHA guidelines and are designed for bedside placement.

Why is the Power-Trialysis® Catheter suture wing transparent and rotatable?

Transparent, rotatable wing allows for easy visualization and cleaning of exit site.

What is included in the kit/tray to dilate prior to placing the Power-Trialysis® Catheter?

Each kit/tray includes an 11-13 Fr. Dualator® Vessel Dilator and a 12-14 Fr. Dualator® Vessel Dilator. Placers should dilate to the largest portion of each Dualator® Vessel Dilator to allow the catheter to more easily enter the tissue and vessel.

PLACEMENT, MAINTENANCE AND CARE

In what veins is the Power-Trialysis® Catheter intended to be placed?

The Power-Trialysis® Catheter is intended to be inserted in the jugular, femoral, or subclavian vein as required.

What is recommended to maintain patency of the Power-Trialysis® Catheter dialysis lumens between hemodialysis, hemoperfusion, or apheresis treatments?

It is recommended that each dialysis lumen be locked with a heparin concentration per institutional protocol. The total volume of each solution must be equal to the internal volume of each lumen. The priming volume is indicated on each lumen.

What is recommended to maintain patency of the Power-Trialysis® Catheter third lumen between intravenous therapy treatments, blood draws, power injection of contrast media, and central venous presume monitoring?

The third distal (purple) lumen should be maintained per institutional protocol for central lines.

Where should the tip of the Power-Trialysis® Catheter be placed?

Placement of the tip is up to the placing physician. NKF K/DOQI guidelines recommend that for acute dialysis catheters placed in the jugular or subclavian vein, the tip be placed in the caval atrial junction or the superior vena cava.

What cleaning agents are recommended for use on the Power-Trialysis® Catheter?

The Power-Trialysis® Dialysis Catheter is compatible with the following agents: Povidone iodine, 0.55% sodium hypochlorite solution, chlorhexidine gluconate 4%, chlorhexidine gluconate 2% solution, dilute aqueous sodium hypochlorite, hydrogen peroxide, bacitracin zinc ointments in petrolatum bases.

WARNING: Acetone and PEG-containing ointments can cause failure of this device and should not be used with polyurethane catheters. Chlorhexidine patches or bacitracin zinc ointments are the preferred alternatives.

Is the Power-Trialysis® Catheter compatible with the StatLock® Catheter Stabilization Device?

Yes. The StatLock® Catheter Stabilization Device is compatible and can be ordered separately from the Bard Medical Division at 800-526-4455. The part number is DI0122.

Can the Power-Trialysis® Catheter be placed femorally?

Yes, the 24 cm and 30 cm lengths are recommended for femoral placements.

Can the Power-Trialysis® Catheter be exchanged over a guidewire?

Yes, the Power-Trialysis® Catheter may be exchanged over a guidewire. The wire included in the kit is a 0.035 inch wire which fits through the third lumen of the catheter.

CENTRAL VENOUS PRESSURE MONITORING

Can central venous pressure monitoring be performed at the same time as dialysis?

No, central venous pressure monitoring should not be performed during hemodialysis, hemoperfusion or apheresis.

Through what lumen can central venous pressure monitoring be performed?

Central venous pressure monitoring is intended to be performed through the distal third (purple) lumen.



Please consult product labels, IFU, and package inserts for any indications, contraindications, hazards, warnings, cautions, and instructions for use.

Bench test data on file.

Specifications

Power-Trialysis® Short-Term Triple Lumen Dialysis Catheter

Code Kit
Configuration
Catheter
Size
Catheter Configuration Insertion Length
(cm) Tip to Cuff
 Package  
5613120 Kit 13.0 Fr Curved Extension Leg 12.5 cm 5 each/case
5613150 Kit 13.0 Fr Curved Extension Leg 15 cm 5 each/case
5613200 Kit 13.0 Fr Curved Extension Leg 20 cm 5 each/case
5613240 Kit 13.0 Fr Curved Extension Leg 24 cm 5 each/case
5615120 Tray 13.0 Fr Curved Extension Leg 12.5 cm 5 each/case
5615150 Tray 13.0 Fr Curved Extension Leg 15 cm 5 each/case
5615200 Tray 13.0 Fr Curved Extension Leg 20 cm 5 each/case
5615240 Tray 13.0 Fr Curved Extension Leg 24 cm 5 each/case
5603150 Kit 13.0 Fr Straight 15 cm 5 each/case
5603200 Kit 13.0 Fr Straight 20 cm 5 each/case
5603240 Kit 13.0 Fr Straight 24 cm 5 each/case
5603300 Kit 13.0 Fr Straight 30 cm 5 each/case
5605150 Tray 13.0 Fr Straight 15 cm 5 each/case
5605200 Tray 13.0 Fr Straight 20 cm 5 each/case
5605240 Tray 13.0 Fr Straight 24 cm 5 each/case
5605300 Tray 13.0 Fr Straight 30 cm 5 each/case
5653120 Kit 13.0 Fr Alphacurve® Catheter 12.5 cm 5 each/case
5653150 Kit 13.0 Fr Alphacurve® Catheter 15 cm 5 each/case
5653200 Kit 13.0 Fr Alphacurve® Catheter 20 cm 5 each/case
5653240 Kit 13.0 Fr Alphacurve® Catheter 24 cm 5 each/case
5655120 Tray 13.0 Fr Alphacurve® Catheter 12.5 cm 5 each/case
5655150 Tray 13.0 Fr Alphacurve® Catheter 15 cm 5 each/case
5655200 Tray 13.0 Fr Alphacurve® Catheter 20 cm 5 each/case
5655240 Tray 13.0 Fr Alphacurve® Catheter 24 cm 5 each/case