Groshong* Peripherally Inserted Catheter
- Three-Way Valve
- No Heparin flush needed
- Silicone Construction
- Latex-Free Components
- Needle-Stick Safety Components
Available sizes: 3 and 4 Fr. Single-Lumen and 5 Fr. Dual-Lumen
Features
The Groshong* PICC... Proven Performance Coupled with Proven Effectiveness
For years Groshong* PICCs have set the standard in closed-system, vascular access delivery...
All catheters include unique Groshong* PICC features:
- Valve Design - reduces blood reflux and clotting
- Three-Way Valve - controls the flow of fluids for infusion therapy
- Reduces Costs - weekly maintenance is reduced to a single saline flush
- Silicone Construction - offers proven biocompatibility for extended indwelling time
- Latex-Free Components - provides options for clinicians/patients with latex allergies
- Needle-Stick Safety Components - enhances clinician/patient safety and facilitates hospital compliance with federal safety regulations
From Single Lumen Groshong* PICC benefits:
- Proximally trimmable - customizes to individual patient’s anatomy
- Clamp-free configuration - no need for clamps on the extension legs because of the unique valve
- Ease of identification - blue color of the catheter quickly identifies the device as a Groshong* PICC...
To Dual Lumen Groshong* NXT PICC advantages:
- Enhanced durability - increases catheter strength
- Equal sized lumens - enhances flow rates allowing for any type of fluid therapy in both lumens
- Reverse taper design - strengthens the external portion of the catheter and tamponades bleeding at the insertion site
- Improved radiopacity - compared to first generation Groshong* PICCs and allows the clinician to follow the PICC from the insertion site to the SVC
Please consult product labels, IFU and package inserts for any indications, contraindications, hazards, warnings, cautions and instructions for use.
Specifications
Groshong* PICC
| Catheter Size | Lumens | Lumen Gauge Size | Average Gravity Flow Rate | Priming Volumes | Lumen Size I.D. |
|---|---|---|---|---|---|
| 3 Fr | Single | 20 Ga. | 246 ml/hr | 0.22 ml | 0.024 in. |
Groshong* NXT ClearVue* PICC
| Catheter Size | Lumens | Lumen Gauge Size | Average Gravity Flow Rate | Priming Volumes | Lumen Size I.D. |
|---|---|---|---|---|---|
| 4 Fr | Single | 18 Ga. | 540 ml/hr | 0.45 ml | 0.033 in. |
Groshong* NXT PICC
| Catheter Size | Lumens | Length | Lumen Gauge Size | Average Gravity Flow Rate |
Priming Volumes | Lumen Size I.D. |
|---|---|---|---|---|---|---|
| 5 Fr | Dual | 45 cm | 19 Ga./ 19 Ga. | 266 ml/hr | 0.35 ml | 0.026 in. / 0.026 in. |
| 5 Fr | Dual | 55 cm | 19 Ga./ 19 Ga. | 193 ml/hr | 0.41 ml | 0.026 in. / 0.026 in. |
Groshong* NXT PICC
| Product Code | Description | Tray | Length | Lumen | Gravity Flow | Priming Volume |
|---|---|---|---|---|---|---|
| 7617408D | 4 Fr SL | Integrated Max Barrier | 18 | 540 | 0.45 | |
| 7827508D | 5 Fr DL | Integrated Max Barrier | 45cm | 19 | 266 | 0.35 |
| 7927508D | 5 Fr DL | Integrated Max Barrier | 55cm | 19 | 193 | 0.41 |
| 9617408D | 4 Fr SL, TLS | Integrated Max Barrier | 18 | 540 | 0.45 | |
| 9827508D | 5 Fr DL, TLS | Integrated Max Barrier | 45cm | 19 | 266 | 0.35 |
| 9927508D | 5 Fr DL, TLS | Integrated Max Barrier | 55cm | 19 | 193 | 0.41 |
Resources
Please refer to the below-listed Instructions for Use (IFUs) for any indications, contraindications, hazards, warnings and cautions.