Sapiens* Tip Confirmation System

Sapiens* Tip Confirmation System

Sapiens* Tip Confirmation System image
  • Helps to position PICC tip in proximity to the cavoatrial junction in adult patients
  • Allows for prompt infusion therapy and immediate release of the PICC line as compared to chest X-ray and other post-procedural confirmation methods
  • Eliminates costs associated with confirmatory chest X-ray
  • Provides immediate feedback to the
    clinician on PICC tip position
  • Eliminates time previously spent waiting
    for X-ray confirmation readings
  • Eliminates X-ray exposure to the
    patient and clinician


Any alterations of cardiac rhythms that change the normal presentation of the P-wave limit the use of this technology. In these instances, confirm PICC tip location using an alternative method. Please consult Instructions for Use for additional safety information.

Features

Sapiens product

The Sapiens* Tip Confirmation System (TCS) is indicated for guidance and positioning of Peripherally Inserted Central Catheters (PICCs). Sapiens* TCS provides real-time catheter tip location information by using the patient's cardiac electrical activity.
Sapiens* TCS is indicated for use as an alternative method to chest X-ray and fluoroscopy for PICC tip placement confirmation in adult patients.

Two clinical studies involving 362 patients have shown that catheter tip placement using the Sapiens* technology was confirmed with chest X-ray or fluoroscopy to be at the desired location in 97% of the cases.

  • 97% at the cavoatrial junction or within +/- 1 cm
  • 3% in middle or lower SVC greater than 1 cm and up to 3 cm away from the cavoatrial junction
  • No adverse events or complications were reported

Data on File (Bard Access Systems, Inc., Salt Lake City, Utah)

Features

  • Dynamic ECG waveform
    Changes in P-wave morphology allow clinician to position catheter tip at a specific/desired location relative to the
    cavoatrial junction
  • Static ECG baseline
    Provides comparative ECG waveform for interpretation of P-wave changes and to assist in maximum P-wave identification
  • Ability to maintain sterile field
    Through-drape connection allows clinician to maintain maximal barrier sterile field during placement
    Probe and wireless remote allow the clinician to maintain sterility while interfacing with Sapiens* TCS
  • Tip location documentation
    Allows for PICC tip location to be easily documented in patient's chart or stored in a computer database
  • Meet guidelines
    By helping to position the PICC tip in proximity to the cavoatrial junction, the Sapiens* TCS technology helps clinicians comply with AVA and INS guidelines for proper PICC tip placement

Benefits

  • Indicated for use as an alternative method to chest X-ray and fluoroscopy for PICC tip placement confirmation in
    adult patients.
  • Allows for immediate confirmation of proper PICC tip position at the bedside and immediate release of the PICC line
    which helps to reduce time to infusion therapy
  • Helps reduce nurse time spent on PICC tip repositioning and improves efficiency associated with PICC
    tip positioning
  • Eliminates costs associated with chest X-ray and time previously spent waiting for X-ray confirmation readings
  • Eliminates X-ray exposure to the patient and clinician when PICC placement is confirmed with Sapiens* TCS
Limitations

Do not rely on ECG signal detection for catheter tip positioning when interpretation of the external or intravascular ECG P-wave is difficult. For example, when:

  • P-wave is not present
  • P-wave is not identifiable
  • P-wave is intermittent

These conditions may be a result of heart rhythm abnormalities, atrial fibrillation, atrial flutter, severe tachycardia or presence of cardiac rhythm devices. In these cases, rely on magnetic navigation and external measurement for tip positioning and use chest X-ray or fluoroscopy to confirm catheter tip location, as indicated by the institutional guidelines and clinical judgment.

Do not rely on ECG signal detection for catheter tip positioning when there are no observable changes in the P-wave. In these cases, rely on magnetic navigation and external measurement for tip positioning and use chest X-ray or fluoroscopy to confirm catheter tip location, as indicated by the institutional guidelines and clinical judgment.

Comprehensive and Integrated Solution

With the addition of Sapiens* TCS, Bard Access Systems now
offers a comprehensive solution combining:

  • Site-Rite* Ultrasound:
    Vessel assessment and access
  • Sherlock* II Tip Location System (TLS):
    Magnetic tip tracking
  • Sapiens* Tip Confirmation System (TCS):
    ECG positioning and confirmation
Sapiens product
Seeing is Believing…
Sapiens product
Sapiens product
See The Vein

Site-Rite* 6 and Site-Rite* VISION

Site-Rite* Ultrasound Systems provide ULTRASOUND GUIDANCE for placement of catheters in vascular structures.

Helps to Meet Industry Guidelines

The Site-Rite* Ultrasound Systems meet AHRQ (Agency for Healthcare Research and Quality) recommendations for use of real-time ultrasound guidance for central line placement.

Decreased Complications1

Clear vessel visualization helps reduce risk of inadvertent arterial puncture, hematoma or pneumothorax.

Reduced Venipunctures1

Reduction in the number of venipuncture kits used to achieve success.

1J. Santolucito. "A retrospective evaluation of the timeliness of physician initiated PICC referrals." Journal of Vascular Access Devices. Fall 2001 pp. 20-26

Sapiens product
See The Tip

Sherlock* II TLS

The Sherlock* II TLS technology provides real-time directional PICC TIP LOCATION and orientation identification via magnetic tip tracking.

Helps reduce risks associated with "blind"
catheter placement

Audible and visual signals indicate location of
tip position with an accuracy of 1 cm

Designed to cover more anatomical landmarks

Sapiens product
See The Wave

Sapiens* TCS

The Sapiens* Tip Confirmation System (TCS) is indicated for use as an alternative method to chest X-ray and fluoroscopy
for PICC tip placement confirmation in adult patients.

Sapiens* TCS helps to position the PICC tip in proximity
to the cavoatrial junction when the patient's P-wave is
present, identifiable, and consistent and allows for
IMMEDIATE CONFIRMATION of PICC tip position
at the patient's bedside.

Allows for immediate release of the
PICC line which helps to reduce time to
infusion therapy

Helps reduce nurse time spent
on PICC tip repositioning and
improves efficiency associated
with PICC tip positioning

Eliminates costs
associated with
chest X-ray
and time
previously spent waiting
for X-ray confirmation readings

Eliminates X-ray exposure to the patient and
clinician when PICC placement is confirmed with Sapiens* TCS

Sapiens product
As compared to chest X-ray and other post-procedural confirmation methods

Please consult product labels and inserts for any indications, contraindications, hazards, warnings, cautions and instructions for use.

Specifications

PowerPICC SOLO*2 Catheters with Sherlock 3CG* TPS Stylet for use with Sapiens* TCS

Product Code Type of Catheter Tray
1194108D 4 Fr. SL PowerPICC SOLO*2 Catheter Max Barrier Tray
1194108 4 Fr. SL PowerPICC SOLO*2 Catheter Full Tray
1295108D 5 Fr. DL PowerPICC SOLO*2 Catheter Max Barrier Tray
1295108 5 Fr. DL PowerPICC SOLO*2 Catheter Full Tray
1396108D 6 Fr. TL PowerPICC SOLO*2 Catheter Max Barrier Tray
1396108 6 Fr. TL PowerPICC SOLO*2 Catheter Full Tray

PowerPICC* Catheters with Sherlock 3CG* TPS Stylet for use with Sapiens* TCS

Product Code Type of Catheter Tray
1174108D 4 Fr. SL PowerPICC* Catheter Max Barrier Tray
1174108 4 Fr. SL PowerPICC* Catheter Full Tray
1175108D 5 Fr. SL PowerPICC* Catheter Max Barrier Tray
1175108 5 Fr. SL PowerPICC* Catheter Full Tray
1275108D 5 Fr. DL PowerPICC* Catheter Max Barrier Tray
1275108 5 Fr. DL PowerPICC* Catheter Full Tray
1385108D 5 Fr. TL PowerPICC* Catheter Max Barrier Tray
1385108 5 Fr. TL PowerPICC* Catheter Full Tray
1386108D 6 Fr. TL PowerPICC* Catheter Max Barrier Tray
1386108 6 Fr. TL PowerPICC* Catheter Full Tray

Sapiens* TCS Hardware

Product Code Description
9770101 Sapiens* TCS for Site~Rite Vision* System (Includes Sherlock* II TLS Sensor and mounting hardware)
9770102 Sapiens* TCS for Site~Rite* 5 or Site-Rite* 6 System (Includes Sherlock* II TLS Sensor and mounting hardware)
9770103 Standalone Sapiens* TCS (Includes Sherlock* II TLS Sensor, ECG Module, Remote Control, Display and Display
Power Supply)
9770104 Sapiens* TCS Display and Display Power Supply
9770068 Sapiens* TCS Remote Control

Product codes 9770101 & 9770102 include the following to upgrade Site~Rite* 5, Site~Rite* 6 and Site~Rite Vision* Systems to Sapiens* TCS: Mounting Arm & Counterbalance, Display, Display Power Supply, ECG Module, Remote Control, and Sherlock* II TLS Sensor.

Kit Components

Description Maximal Barrier Standard Tray Full Tray
PICC
Microintroducer (length and size PICC dependent)
Guidewire, 0.018 in.
Scalpel, safety
IV catheter, 20 Ga.
Introducer needle, 21 Ga.
Needle hypodermic, safety, 25 Ga.
Filter straw
Wound closures (pkg of three)
Transparent dressing
Drape, fenestrated
Drape, full body, fenestrated
Bouffant cap
Surgical gown
Towel, absorbent
Poly underdrape
Tourniquet, latex-free
Face mask
Surgical tape
Scissors
Measuring tape
End cap (one per PICC lumen)
Syringes
Surgical gloves, sterile, latex-free
2 ChloraPrep* solution one-step applicator (1 tinted, 1 clear)
Lidocaine
Saline
Alcohol wipe
Gauze pad, 4 in. x 4 in.
Gauze pad, 2 in. x 2 in.
StatLock* catheter stabilization device
ECG Electrodes (3) and Leads Assembly
Remote Control Holder and Elastic Bands
Patient Checklist
Room Stop Sign
Patient Safety Guide